Machine Dental Lab

Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA


Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA
Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA

Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA   Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA

This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays). Quency of this machine is 30 KHz.

And the tube current is 1 MA. The radiation scope is at an angle of 24 degrees.

Located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the Green X-ray Machine. Focal Spot To Skin Distance. Reference of the time of exposure. Operation of the Main Unit. Make sure the fittings on the encasement list are packaged within the box. Install the blue ray tube to the foreside of the ball headthen tighten it. The pilot lamp will be light up.

During this timethe digital tube will show the fore se. Now the equipment is in standby mode. Ing the time (Skip to next step if unneeded) Use the "SET""+"and" -" buttons to reset the time as follows: press SETthe pilot lamp above is illuminated the machine is now in the time setting mode. Then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off.

The equipment is now in standby mode. Put the Tooth film plumb behind the tooth which is going to be taken picture and be as close as possible the smooth side stick to the t. Keep the ball head plumb to the tooth projection position; Have the ball headtooth and tooth film steadily mutually plumb.

After positioninguse the ON/OFF on the main Unit to take pictures. (Notice: gently press 0.5 sec to turn it on). After exposure to the tubepress the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output rayso the dental films can be used again).

Repeat step 6 to reset the picturing time. To repeat the picturing processplease repeat steps 7 to 9.

Turn the power off when the work is. Edpress POWER making sure the pilot lamp is. Don't keep the ma. Make sure the angle of filmtoothand ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing.

Making sure that there is no change in any of their positions. Remember to turn the power 0. Ge the battery if t.

He machine cannot work and the red lamp lignt. After turning the power onwait one minute before taking picturesthis allows the ray to provide a steady ou. The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs it will not be able to carry out the normal work of.

ON/OFF button could stop the objection and then the machine goes back to the preparation mode. Use high quality tooth film and developing liquid to make clear pictures.

Handle the ball head gently while in useso as not to damage the delicate component. We usually set the time between 3-8 seconds when taking pictur. But the actual time of ray output is 0.2-0.5 seconds. Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.

Accordance with the scope of the technical parameters. Please read the manual carefully before using. The sale of this item may be subject to regulation by the U. Food and Drug Administration and state and local regulatory agencies. Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely.

Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. That came with your order. These will be used to verify claims if there is any problem with you. If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout.

All items must be paid within 7 days. Serivce is our 1st priority at Baistra! We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face.

We stand behind our products and pride ourselves on OUTSTANDING customer service. The item "Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA" is in sale since Friday, February 2, 2018. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\X-Ray Machines & Equipment\Other X-Ray Equipment". The seller is "baistraworld" and is located in Fullerton, California. This item can be shipped to United States.

  1. Tube Current: 1mA
  2. Model: BLX-8Plus
  3. Modified Item: No
  4. Country/Region of Manufacture: China
  5. Custom Bundle: No
  6. Time Exposure: 1~~9s
  7. High pressure generator: 30kHz DC
  8. Rated Power: 60w
  9. Bundle Listing: Yes
  10. Focal Spot To Skin Distance: >20CM
  11. Tube Voltage: 60kV
  12. Non-Domestic Product: No
  13. MPN: GJ1170100500
  14. Brand: BLX-8Plus
  15. Intended Use/Discipline: Dental Laboratory

Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA   Portable Dental Digital X-Ray Imaging System Mobile Machine Unit BLX-8Plus USA